Primary: 110/230 volts 60 Hz
Secondary: 18/36 volts
(two 18V @ 139mA or one 18V @ 278mA or one 36V @ 139mA)

110/230v 60Hz Primary; Two secondaries 18v, 139ma, (No load 25.5v, 2ma), 70% eff. For 110v supply power, primaries must be parallel; for 230v operation, primaries must be in series. OD: 47.mm ID: 6.mm x 18mm H

Primary: 110/230 volts 60 Hz
Secondary: 7/14 volts
(two 7V @ 500mA or one 7V @ 1A or one 14V @ 500mA)

110/230v 60Hz Primary; Two secondaries 7v, 500ma, (No load 9.5v, 3ma), 74% eff. For 110v supply power, primaries must be parallel; for 230v operation, primaries must be in series. OD: 47.mm ID: 6.mm x 21.5mm H

Primary: 110/230 volts 60 Hz
Secondary: 12/24 volts
(two 12V @ 417mA or one 12V @ 834mA or one 24V @ 417mA)

110/230v 60Hz Primary; Two secondaries 12v, 417ma, (No load 14.4v, 3ma), 82% eff. For 110v supply power, primaries must be parallel; for 230v operation, primaries must be in series. OD: 53.5mm ID: 6.8mm x 23.5mm H

Primary: 110/230 volts 60 Hz
Secondary: 12/24 volts
(two 12V @ 2.08A or one 12V @ 4.16A or one 24V @ 2.08A)

110/230v 60Hz Primary; Two secondaries 12v, 2.08amp, (No load 13.8v, 8ma), 86% eff. For 110v supply power, primaries must be parallel; for 230v operation, primaries must be in series. OD: 78.mm ID: 22.5mm x 35.mm H

Primary: 117/234 volts 50/60 Hz
Secondary: 9/18 volts
(two 9V @ 1.67A or one 9V @ 3.3A or one 18V @ 1.67A)

Two 117v 50/60Hz International Primaries; Two secondaries 9v, 1.67amp, 30VA. 3"DIA x 1.5"H 1.1lbs. UL & CSA recognized/certified. 10" Color coded leads. Class A 105°C. Primaries must be connected in series or parallel.

Primary: 117/234 volts 50/60 Hz
Secondary: 9/18 volts
(two 9V @ 5.3A or one 9V @ 10.6A or one 18V @ 5.3A)

Two 117v 50/60Hz International Primaries; Two secondaries 9v, 5.3amp, 95VA. 3.9"DIA x 1.5"H 2.2lbs. UL & CSA recognized/certified. 10" Color coded leads. Class A 105°C. Primaries must be connected in series or parallel.

Primary: 117/234 volts 50/60 Hz
Secondary: 15/30 volts
(two 15V @ 3.2A or one 15V @ 6.4A or one 30V @ 3.2A)

Two 117v 50/60Hz International Primaries; Two secondaries 15v, 3.2amp, 95VA. 3.9"DIA x 1.5"H 2.2lbs. UL & CSA recognized/certified. 10" Color coded leads. Class A 105°C. Primaries must be connected in series or parallel.

Primary: 117/234 volts 50/60 Hz
Secondary: 18/36 volts
(two 18V @ 3.9A or one 18V @ 7.8A or one 36V @ 3.9A)

Two 117v 50/60Hz International Primaries; Two secondaries 18v, 3.9amp, 140VA. 3.9"DIA x 1.9"H 3lbs. UL & CSA recognized/certified. 10" Color coded leads. Class A 105°C. Primaries must be connected in series or parallel.

Primary: 117/234 volts 50/60 Hz
Secondary: 15/30 volts
(two 15V @ 10A or one 15V @ 20A or one 30V @ 10A)

Two 117v 50/60Hz International Primaries; Two secondaries 15v, 10amp, 300VA. 4.6"DIA x 2.6"H 5.7lbs. UL & CSA recognized/certified. 10" Color coded leads. Class A 105°C. Primaries must be connected in series or parallel.

Primary: 117/234 volts 50/60 Hz
Secondary: 30/60 volts
(two 30V @ 7.7A or one 30V @ 15.4 or one 60 @ 7.7A)

Two 117v 50/60Hz International Primaries; Two secondaries 30v, 7.7amp, 460VA. 5.4"DIA x 2.6"H 7.9lbs. UL & CSA recognized/certified. 10" Color coded leads. Class A 105°C.

Primary: 117/234 volts 50/60 Hz
Secondary: 24/48 volts
(two 24V @ 13A or one 24V @ 26A or one 48V @ 13A)

Two 117v 50/60Hz International Primaries; Two secondaries 24v, 13amp, 625VA. 5.5"DIA x 3.2"H 9.5lbs. UL & CSA recognized/certified. 10" Color coded leads. Class A 105°C. Primaries must be connected in series or parallel.

Primary: 117/234 volts 50/60 Hz
Secondary: 30/60 volts
(two 30V @ 10.4A or one 30V @ 20.8A or one 60V @ 10.4A)

Two 117v 50/60Hz International Primaries; Two secondaries 30v, 10.4amp, 625VA. 5.5"DIA x 3.2"H 9.5lbs. UL & CSA recognized/certified. 10" Color coded leads. Class A 105°C.

Primary: 120/230 volts AC 50/60 Hz
Secondary: 6.3/14.8/64/195/390 volts (6.3v @ 3.6A, 14.8v @ 2A, 64v @ 100mA, 195 @ 500mA, and 195/390 @ 1.5A)
Apparent Power: 740 VA

Tortran vacuum tube amplifier transformer. Center epoxy potted with 3/8" mount hole. Dual primaries 115v (230v in series) 50/60Hz 740va. Five secondaries 390v C.T. at 1.5 amps, 195v at 0.5 amps, 14.8v at 2 amps, 6.3v at 3.6 amps, 64v at 0.1 amps. 6.1"DIA x 3"H, 14 lbs.

Primary: 117/234 volts 50/60 Hz
Secondary: 55/110 volts
(two 55V @ 9A or one 55V @ 18A or one 110V @ 9A)

Two 117v 50/60Hz International Primaries; Two secondaries 55v, 9amp, 990VA. 6.5"DIA x 3"H 15.2lbs. UL & CSA recognized/certified. 10" Color coded leads. Class A 105°C.

Primary: 100/120/220/240 volts 50/60 Hz
Secondary: 110 volts @ 1.92A
Apparent Power: 230 VA

Quad 100/120/220/240v 50/60Hz primaries; One secondary 110v, 1.92 amp, 230VA. 4.6"DIA x 2.4"H 5.2lbs. Multiple primaries must be connected in series or parallel.

Primary: 100/120/220/240 volts
Secondary: 110/220 volts
(two 110V @ 2.5A or one 110V @ 5A or 220V @ 2.5A)

Quad 100/120/220/240v 50/60Hz Primaries; Two secondaries 110v, 5amp (240v, 2.5amp), 600VA. 6.2"DIA x 3.1"H 13lbs. Multiple primaries must be connected in series or parallel.

Primary: 100/120/220/240 volts 50/60 Hz
Secondary: 110/220 volts
(two 110V @ 4.16A or one 110V @ 8.3A or 220V @ 4.16A)

Quad 100/120/220/240v 50/60Hz Primaries; Two secondaries 110v, 8.33amp (220v, 4.16amp), 1000VA. 6.9"DIA x 3.5"H 20lbs. Multiple primaries must be connected in series or parallel. Factory new production overrun stock.

Primary: 100/120/220/240 volts 50/60 Hz
Secondary: 110/220 volts
(two 110V @ 12.5A or one 110V @ 25A or 220V @ 12.5A)

Quad 100/120/220/240v 50/60Hz Primaries; Two secondaries 110v, 25amp (240v, 12.5amp), 3000VA. 10"DIA x 4.3"H 47lbs. Multiple primaries must be connected in series or parallel.

Primary: 100v / 200v @ 50/60 Hz
Secondary: 500 volts c.t. @ 2 amps or 25 volts @ 4 amps
100 va

Teca toroidal isolation power transformer.

Dimensions: 5-1/2"D x 3"H
Manufactured by
Alt. P/N:

Toroidal transformer. 1 KW. Unknown winding.

Dual Primary: 115 / 230 volts, 1000 watts
Dimensions: 5-1/2" O.D. x 2-3/4"H
Manufactured by TIBI Electronics

TIBI Electronics Toroidal Transformer. Core with low voltage windings. Great project core for rewinding.

Primary: 100v / 200v @ 50/60 Hz
Secondary: 28.4v @ 5.6 amp or 56.8v @ 2.8 amp
Dimensions: 4"D x 1-7/8"H

Teca toroidal power isolation transformer. 160va.