Current Transformers
Raina Current Transformer 221/5
(TM) 221/5
Raina & C current transformer. 1-1/8" x 2-1/4" x 1-3/4".
TRI / 1-177.5.
Raina Current Transformer 221/6
(TM) 221/6
Raina & C current transformer. 1-1/8" x 2-1/4" x 1-3/4".
TRV 1-177.5.
Weston Current Transformer 500/5 Ratio
(MTR) 461-15590
1 turn: 50/25
2 turn: 250/5
5 turn: 100/5
Weston current transformer. 15 va, 50-125 Hz, 1200 line volts. 1 turn: 500/5, 2 turns: 250/5, 5 turns: 100/5. Taps for 0.5, 1, 2.5, 5, 10, 25 & 50 amps. 2-3/4" x 6" x 8" high.
Dwyer Instruments CCS Current Switch
(TM) CCS-231150
1.5 to 200 amps
Dimensions: 1-1/4" x 2-1/2"H
Manufactured by Dwyer Instruments
Dwyer Instruments CCS current switch. Split core-clamp on. Adjustable set point. Contact closes when preset current level is achieved. 3-7/16" mounting center. Attach to any AC load and close a set of alarm contacts when a preset current has been achieved.
Airpax DC Transducer
(SEN) MAS61
Dimensions: 2" x 2-1/4" x 3"
9/32" inner diameter hole @ transducer middle
Manufactured by Airpax
Airpax DC transducer. Wire passes through 9/32" inner diameter hole @ transducer middle. 2" x 2-1/4" x 3"L. Gates / Harris P/N: 741-0001-000.
Vitec Current Sense 20amp PC Board mount Transformer
(TM) 57P1820G
20 amps maximum
300 turns
DCR 11 ohms, 180 mH
Vitec current sense transformer for switching power supply. 20 amps peak. 300 turns. DCR 11 ohms, 180 mH. Vitec calls these "Current Sense Inductors."
Vitec Current Sense Transformer
(TM) 57P1822
DCR 14 ohms, 73 mH
350 turn ratio
Manufactured by Vitec
Vitec current sense transformer for switching power supply. 350 turn ratio. DCR 14 ohms, 73 mH. Vitec calls these "Current Sense Inductors."
Current Sense Transformer 20 mH / 1 ohm DCR
(TM) D1870L
Inductance = 20 mH / DCR = 1 Ohm
Design frequency: 20 KHz-50KHz
100 turn
Coil Craft Series "D18XX" encapsulated model current sense transformer. 1 volt / amp sensitivity. 200ohm terminating resistor typically required. 100 turn. Maximum 24 amp. Design frequency = 20 KHz - 50 KHz (switcher power supplies). Inductance = 20 mH, DCR = 1 ohm. DC = 2005. 5/8" x 3/4" x 3/8". 1/2" lead spacing. 70,000 pcs available. Power-Mag P/N: CT10M100. Packed 405 units per case. For price breaks over 100pcs, must be ordered in multiples of 405 units. (full cases)
Current Sensor 50 amp 3/8" diameter
(TM) CS60-050
1 turn primary
50/60 Hz
50 amp maximum generates 280mV
Coil Craft 50/60 Hz current transformer measures 5-50 amps with a 1 turn primary passing through center hole. Increasing turn increases sensitivity. PC mount (3rd lead pictured is for stability.) 50 amps generates 280 mV typical in secondary. Center hole 3/8" diameter. Overall 7/16" x 1" x 1-1/8" high.
Current Transformer 62.5:1 turns ratio
(TM) LT1879
62.5 : 1 Turns Ratio
Dimensions: 3-3/4" x 4" x 1-1/2". 1-3/8" hole
Alt. P/N: NSN: 5950-00-072-6868
Current transformer. 62.5 : 1 turns ratio. 1-3/8" hole. Model 500, Mfg. P/N: LT1879.
Current Transformer 200:5 Amp Ratio
(TM) 5103
200 : 5 Amp Ratio
50-400 Hz
Dimensions: 1-7/16" diameter center hole. 1-3/16" deep x 3-3/4" wide x 4-1/4" high
Electromagnetic Industries Model 51. 50 - 400 Hz, 5 phase. 1-7/16" diameter center hole. 1-3/16" deep x 3-3/4" wide x 4-1/4" high. P/N: 864362. NSN: 5950-00-250-6949.
Current Transformer 75 Amps
(TM) TRA-TQD901
75 Amps
Dimensions: 1-1/4"L x 7/8"W x 5/16"H
Hical high power current transformer. Surface mount. 1-1/4"L x 7/8"W x 5/16"H. We do not have specs but calculate the max current to be 75 amps.
Current Transformer 208 Amps
(TM) B52-1220-1
208:1.33 ratio
1 turn primary
5 va @ 60 Hz 12.5 va @400 Hz
Electromagnetic Industries. 208 : 1.33 ratio. 5 va @ 60 Hz, 12.5 va @ 400 Hz, all at 1 turn primary. 4-1/4" outside diameter, 1-3/8" inside diameter, 1-1/4" thick. Mfg. P/N: 3-000-004.
Current Transformer 1500:5 Amp Ratio
(TM) W2-152
1500 : 5 Amp Ratio
25-400 Hz
1 turn primary
Square D 25 - 400 Hz, 10kv, current transformer has 5 amp output for 1500 amp load with 1 primary turn. 6-3/4" outside diameter, 4-1/4" inside diameter, 1-1/4" thick.
300 : 5 amp Ratio / 25 - 60 Hz
600v / 10kv test
Dimensions: 4-1/2" inside diameter. 4-1/2" deep x 8-1/2" wide x 10-1/2" high
General Electric heavy duty core cast in rubber. 300:5 Ratio. 25 - 60 Hz. 4-1/2" inside diameter. 4-1/2" deep x 8-1/2" wide x 10-1/2" high. Steel mounting base. 600v / 10kv test.
Current Transformer 250:5 amp Ratio
(TM) SIMPLX100
250 : 5 amp Ratio
Rated 5va
Dimensions: 1-1/8" hole 3" square x 1-1/2" wide
Simplex 5 va series 100 current transformer. 1-1/8" hole. 250 amp load creates 5 amp signal. 3" square x 1-1/2" wide.
1 Turn: 150:5/300:5/600:5/900:5 amp ratio
2 Turns: 75:5/150:5/300:5/150:5 amp ratio
750 volts maximum
R.B. Annis Co. current transformer. Split core. 25-60-400 cycles, up to 750 volts. 1 turn: 150:5/300:5/600:5/900:5 amp ratio. 2 turns: 75:5/150:5/300:5/450:5 amp ratio. 7" x 4" x 7". Window dimension 41mm X 89mm (1.6" X 3.5").
Type JP-1 Current Transformer 600:5 or 800:5
(TM) 750X99G1
1 Turn: 10:5/20:5/50:5/100:5/600:5/800:5 amp ratio
2 Turns: 5:5/10:5/25:5/50:5/300:5/400:5 amp ratio
25-60Hz
General Electric instrument current transformer. 1 turn: 10:5/20:5/50:5/100:5/600:5/800:5 amp ratio. .2 Turns: 2/ 4 / 10 / 20 / 120 / 160 : 1. For 600 volt circuit. 9-1/2" x 4" x 9-3/4". Excellent condition.
Current Transformer 600 amps 120:1 ratio
(TM) CN-1
600 amp load @ 12.5 va gives 5 amp output
120:1 Ratio
Dimensions: 9" wide x 6" deep x 5-1/2" high 2" square silver plated lugs with 9/16" holes
BBC ITE current transformer has 5 amp output for 600 amp load @ 12.5 va. Primary has huge 2" square silver plated lugs with 9/16" holes. Maximum dimension: 9" wide x 6" deep x 5-1/2" high.
Current Transformer 195:5 amp Ratio
(TM) 13206E4532-1
195:5 amp Ratio
25-800 Hz (cps) ASA accuracy @ 60 cps
Rated 5 va @ 60 cps
Weston current transformer. 195 : 5 amp ratio, 25 - 800 cps, 5 va @ 60 cps. ASA accuracy @ 60 cps. 0.6B-0.1 / 1.2B-0.2. 3-5/8" square, 1-1/2" I.D. hole. NSN: 5950-00-015-0083.
Current Transformer 800:5 amp Ratio
(TM) 7SFT801
800:5 Amp Ratio
600v
50-400 Hz
Instrument Transformers Inc. 50-400 Hz current transformer has 5 amp output for 800 amp load with 1 primary turn. 600v. Ins. Class 10kv. 2-1/2" diameter center hole. 1" deep x 4-1/2" wide x 5-1/4" high. NSN: 5905-01-248-1448.
Current Transformer
(TM) 7SFT901
900 : 5 amp Ratio
1 turn primary
50-400 Hz
Instrument Transformers Inc. 50 - 400 Hz current transformer has 5 amp output for 900 amp load with 1 primary turn. 2-1/2" diameter center hole. 1" deep x 4-1/4" wide x 5-1/4" high.
Current Transformer 23,000:1 amp Ratio
(TM) K5546
23,000:1 amp Ratio
115 amps primary current generates 0.005 amps in the coil
Dimensions: 3-1/4" high, 1-1/8" diameter center hole, 1" deep coil, 2-1/4" wide at the base
Keytronics 115 amps primary current generates 0.005 amps in the coil. 3-1/4" high, 1-1/8" diameter center hole, 1" deep coil, 2-1/4" wide at the base.
Current Transformer 3 Phase / 156:2 amp Ratio
(TM) 33-156-2
3 Phase
156:2 amp Ratio
50-400 hz
50 - 400 Hz current transformer has two amp output for 156 amp load. 1" diameter center holes. 1" deep x 3-1/4" wide x 7" high. Each phase terminated at top.
2,500V maximum line voltage Current Transformer
(MTR) 461-12160
1 Turn 800:5 Ratio, 2 Turns 400:5 amp Ratio
Max Line Voltage up to 2,500v
Rated 15 VA max.
Weston current transformer. 1 Turn: 800:5 amp ratio, 2 Turns: 400:5 ratio. Max line voltage: 2500v. Max 15 VA. 25-500Hz Dimensions: 6"W x 8"H x 2-3/4"D. 1-5/8" inside hole diameter. Used, good condition. Checks out ok.
2,500V maximum line voltage Current Transformer
(MTR) TR-2A
Max Line Voltage: 2500v
800:5 amp Ratio
Rated up to 15VA
Sensitive Researchcurrent transformer. Same as (MTR) 461-12160. 1 Turn: 800:5 amp ratio, 2 Turns: 400:5 ratio. Max line voltage: 2500v. Max 15 VA. 25-500Hz Dimensions: 6"W x 8"H x 2-3/4"D. 1-5/8" inside hole diameter. Used, good condition except cracked case near secondary terminals and possibly a burn (see photo). Checks out ok. Sold As-Is, no returns.
2:1/5:1/10:1/20:1/100:1/200:1 amp Ratio
Up to 750 line volts
Rated up to 2 VA
Weston portable, adjustable current transformer. 25 - 400 Hz. 2 va. Up to 750 line volts. 1-5/8" inside hole diameter. 4" deep x 1-7/8" wide x 5-1/2" high.
Current Transformer 2.5VA
(TM) A6301
2.5 va
15/16" center hole
An AC current flowing through the 15/16" center hole creates a monitor current in the transformer, limited to 2.5 va.
Current Transformer 600:5 amp Ratio
(TM) 750X10G8
600:5 ratio
25-400 Hz
Dimensions: 4-1/2"D x 8-1/2"W x 10-1/2"H
General Electric 600 amp, 600:5 Ratio. 25 - 400 Hz. Dimensions: 4-1/2" deep x 8-1/2" wide x 10-1/2" high. 4-1/2" inside diameter.
Current Transformer 300:5 amp ratio maximum 600 amps
(TM) 750X10G5
300:5 ratio
25-400 Hz
Dimensions: 4-1/2"D x 8-1/2"W x 10-1/2"H
General Electric 600 amp max, 300:5 Ratio. 25 - 400 Hz. Dimensions: 4-1/2" deep x 8-1/2" wide x 10-1/2" high. 4-1/2" inside diameter.
Current Transformer 100 amps
(TM) MC15-C71-1346-120
25-60 Hz
Insulation 15 KV
Manufactured by I-T-E
I-T-E Circuit Breaker. 100:5 ratio produces 5 amps secondary for one turn 100 amp primary. 15kv / 95kv imp. level. 2" inside diameter. 7-1/4" deep x 7" diameter x 10-1/4" high.
GE Current Transformer 1200:5 Amp Ratio, 10kVA
(TM) PLCT4G07
1200:5 Amp Ratio
10,000V
3.7" x 7.5" Opening
GE current transformer. Ratio 1200:5 amps. 10 kv. 3.7" x 7.5" opening. MS27391.
Inductance: 80mH (min)
Design Frequency: 1-1,000KHz
200 turn
Coil Craft current sense transformer. 5.7 terminating ohm. 1-1000KHz. 35 amp (max). 200 turns. 596Vus volt time product.
Crompton Current Transformer 100:5 amp Ratio
(TM) 805-943U-PKLS-K
100:5 amp Ratio
600v
50-400Hz
Crompton current transformer. 100:5 amp ratio. 600v, 50-400Hz. 1-9/16" hole.
Crompton Current Transformer 250:5 amp Ratio
(TM) 805-943U-RSLS-K
250:5 amp Ratio
600v
50-400Hz
Crompton current transformer. 250:5 amp ratio. 600v, 50-400Hz. 1-9/16"D hole.
Current Transformer 300:5 amp Ratio
(TM) 5RBL-301
300:5 amp Ratio
50-400Hz
Dimensions: 1-9/16" I.D x 3-5/8"H
Current transformer. 300:5 amp ratio, 12.5VA, 600v, 50-400Hz. 10kv test.
Current Transformer 200:5 amp Ratio
(TM) 170RL-201
50 - 400 Hz
600v
10kv Isolation
Instrument Transformers Inc. current transformer. 200:5 amp ratio. 50 - 400 Hz, 600v. 10kv isolation.
Surface Mount Transformer Current Sense
(TM) 3448G
Operating temperature= -40°C to 180°C
Manufactured by GB International
Alt. P/N:
GB International surface mount transformer. Current sense = 70:1 ratio. 500v isolation. 6 amps RMS. Operating temperature= -40ºC to 180ºC. Tape & Reel. 0.325" x 0.260" x 0.228". Power One uses this CT in many different supplies. 1.4 million pieces in stock!! Mfg. P/N: 3448G.
Current Transformer
(TM) PA0001
Pulse Engineering current transformer. Specifications unknown. Made for Power One switching power supply. 0.709" x 0.782" x 0.275"H. Power One P/N: HBD901P. 500,000 pcs in stock!!
Dimensions: 11"L x 4-1/4"H x 1-1/2"W
Manufactured by Technology Research
Alt. P/N: DOD P/N: 72-5333
Technology Research 3 phase current transformer. We do not have specs on this transformer. Each port has 2 screws, H1 & H2, H3 & H4, H5 & H6 that are secondaries for ports A, B, C. Additionally, there are winding C1 & C2, X1, X2, X3 that have continuity respectively. 1-1/4"D cable hole.
WICC Current Transformer
(TM) MW1110
Ratio: 250:5 amps
Burden: 1.1 @ 60 Hz
600v
WICC current transformer. Used.
300 Hz - 200 MHz
Output Volts per Amp: 0.1
10 amps Max RMS
Pearson Electronics pulse current transformer. Model 2878. "SMA" female. Removed, very clean.
DC-200 KHz
+-12 - 15v DC
80 ohm Coil
F.W. Bell closed loop hall effect current sensor. PCB mount. Accurately measures DC and AC currents and provides electrical isolation between the current carrying conductor and the output of the sensor. Made in the USA.
Gould Clamp-On AC Ammeter
(MTR) 633B
Ranges: 10 / 25 / 100 / 250 / 500 / 1000 AC amps
Manufactured by Gould
Alt. P/N:
Gould clamp-on AC ammeter. "Hurtin' For Certain". Meter has been replaced with binding posts. Range selector lever broken.
LEM Current Module
(TM) LB200-S/SP4
±15v DC
30 ohms Int. Res.
1 : 1000 Ratio
LEM current module. Closed loop "Hall Effect" transducer. Made in Geneva Switzerland. DC: 1994.
Meter Shunt Assortment
(MTR) SHUNT-AS3
2"L x 1-5/8"H
50 mV F.S
Meter shunt assortment. 50 mV F.S. 2"L x 1-5/8"H. Includes one of each:
- 30 amp
- 50 amp
- 0.2 amp
- 1 amp
Meter Shunt Assortment
(MTR) SHUNT-AS4
Meter shunt assortment
Meter shunt assortment. Includes one of each:
- CAT0042211: 5 amp - 50 mV / 10 amp - 100 mV
- MSA200: 20 amp - 50 mV
- 8406-3: 5 amp - 100 mV
- 8200-.02: 0.2 amp - 50 mV
GE Current Transformer
(TM) JCD-3
1200:5 amp ratio
5kV / BIL 60kV
Grid grade - outdoor
GE current transformer. 1200:5 amp ratio, 60kV. 5kV/BIL 60kV. Grid grade - outdoor. 18" L x 19" H x 12" W. 5-1/2" DIA conductor opening. 130 pounds. Catalog No. 753X031008. New-unused.
Current Sense Transformer 20mH / DCR = 1.4 ohm
(TM) 57P1687
Inductance = 20 mH / DCR = 1.4 Ohm
15.75 kv, 20KHz to 200KHz
100 turns
Pulse Engineering current sense transformer. 100 turns. 1.4 ohm primary DCR. 300 ma, 20 mH secondary Ind. 15.75 kv, 20 KHz to 200 KHz. 20 amp maximum. Operating a current transformer as a voltage transformer provides a cost-effective alternative to injection transformers sold as test accessories (see PDF). 600 pcs per case. Quantity breaks above 100pcs requires orders in multiples of 600 units. (full cases).
Current Transformer 200/400:5 amp
(TM) DEP20805-7684
4 3/4" ID hole. 24" x 13" x 21" tall
Manufactured by ABB
Alt. P/N:
ABB current transformer. 200/400:5 amp. Also LG-25-585. NSV 25.5kv BIL 150kv. 4 3/4" ID hole. 24" x 13" x 21" tall. 135lbs. New.
ABB Current Transformer 800: 5amp Ratio
(TM) PEC20801122
5 1/4" x 6 3/8"H x 4 3/8"D. 2 1/2" Hole.
Manufactured by ABB
Alt. P/N:
ABB current transformer. 5 1/4" x 6 3/8"H x 4 3/8"D. 2 1/2" Hole. NSV 600 BIL 10kv. 800: 5amp Ratio. New.
ABB Current Transformer 1000:5 amp Ratio
(TM) PEC20801304
8"W x 10 1/4" H x 2 1/2" Deep. 5 1/2" ID
Manufactured by ABB
Alt. P/N:
ABBcurrent transformer. 8"W x 10 1/4" H x 2 1/2" Deep. 5 1/2" ID. 1000:5 amp Ratio. NSV-600v BIL-10kv.
ABB Current Transformer 400:5 amp - 800:5 amp
(TM) LG-15-585
20" x 14" Deep x 21 1/2" H
Manufactured by ABB
Alt. P/N:
ABB current transformer. 20" x 14" Deep x 21 1/2" H. 4 3/4" D hole. 400:5 amp 800:5 amp. 15kv NSV 110 kv BIL. New.
ABB Current Transformer 1000: 5amps Ratio
(TM) PEC20801304-B
8"W x 10 1/4" H x 2 1/2" Deep. 5 1/2" ID
Manufactured by ABB
Alt. P/N:
ABBcurrent transformer. 8 1/4"W x 10 1/4" H x 2 1/2" Deep. 5 1/2" ID. 1000:5 amp Ratio. NSV-600v BIL-10kv. With Mounting Bracket.
ABB Current Transformer 2000: 5amps Ratio
(TM) PEC20801338
8 1/4" x 10 1/2" H x 2 5/8" Deep. 5 1/2" ID Hole.
Manufactured by ABB
Alt. P/N:
ABBcurrent transformer. 8 1/4" x 10 1/2" H x 2 5/8" Deep. 5 1/2" ID Hole. 2000:5 amp Ratio. NSV-600v BIL-10kv. Also Type CLC
ABB Current Transformer 100: 5amps Ratio
(TM) PEC20801072
5 1/4" x 6 7/8" x 2 1/2" ID hole. 5 1/2" ID
Manufactured by ABB
Alt. P/N:
ABBcurrent transformer. 5 1/4" x 6 7/8" x 2 1/2" ID hole. 5 1/2" ID. 100:5 amp Ratio. NSV-600v BIL-10kv. New.
ABB Current Transformer 2000: 5amps Ratio
(TM) CPL20808085H
6"D x 8 1/2" H x 2 1/8" D. 3 1/2 x 4 1/2 Oval hole
Manufactured by ABB
Alt. P/N:
ABBcurrent transformer. 6"D x 8 1/2" H x 2 1/8" D. 3 1/2 x 4 1/2 Oval hole. 2000:5 amp Ratio. NSV-600v BIL-10kv. Also CMV.
ABB Current Transformer 2000: 5amps Ratio
(TM) CPL20801338
8 1/8"W x 10 1/2" H x 2 1/2" Deep. 5 1/2" ID
Manufactured by ABB
Alt. P/N:
ABBcurrent transformer. 8 1/8"W x 10 1/2" H x 2 1/2" Deep. 5 1/2" ID. 2000:5 amp Ratio. NSV-600v BIL-10kv. 60Hz.
ABB Current Transformer 400: 5amps Ratio
(TM) 755C150014
13" x 11" x 15" Tall
Manufactured by ABB
Alt. P/N:
ABBcurrent transformer. 13" x 11" x 15" Tall. 400:5 amp Ratio. 65 lbs. NSV-15kv BIL-110kv. 50-60Hz. JKW-5C. New.
GE Potential Transformer 60: 1amps Ratio
(TM) 765C131101
14" x 12" x 16" Tall.
Manufactured by GE
Alt. P/N:
GEpotential transformer primary 7200v AC. 14" x 12" x 16" Tall. 61lbs. 60:1 amp Ratio. BIL-110kv. 60Hz. Also JVW-110C. 1000VA. Single bushing. New.
GE Transformer 600/1200: 5amps Ratio
(TM) 755X031729
23" x 13" x 19" Tall. 5 5/8" ID
Manufactured by GE
Alt. P/N:
GEtransformer. 23" x 13" x 19" Tall. 5 5/8" ID. 600/1200:5 amp Ratio. NSV-14.4kv BIL-110kv. JCD-5.
GE Current Transformer 600/1200: 5amps Ratio
(TM) 755X31G16
11 1/2" x 23" H. 5 5/8" D hole.
Manufactured by GE
Alt. P/N:
GEcurrent transformer. 11 1/2" x 23" H. 5 5/8" D hole. 600/1200: 5 amp Ratio. NSV-14.4v BIL-110kv. Also 755 x 31G16 JCD-5.
ABB Current Transformer 2000: 5amps Ratio
(TM) PEC20808085
6"D x 8 1/2" H x 2 1/8" Deep. 3 1/2" x 4 1/2" ID oval hole
Manufactured by ABB
Alt. P/N:
ABBcurrent transformer. 6"D x 8 1/2" H x 2 1/8" Deep. 3 1/2" x 4 1/2" ID oval hole. 2000:5 amp Ratio. NSV-600v BIL-10kv. Also CMV-HT
GE Transformer 600/1200: 5amps Ratio
(TM) 755X030009
32" x 10" x 16" Tall.
Manufactured by GE
Alt. P/N:
GE transformer. 32" x 10" x 16" Tall. 97lbs. Also JCW-5. 600/1200:5 amp Ratio. NSV-14.4kv BIL-110kv. New.
GE Current Transformer 600/1200: 5amps Ratio
(TM) 753X031016
18" x 12.5" x 19" Tall. 5 1/2" ID
Manufactured by GE
Alt. P/N:
GEcurrent transformer. 18" x 12.5" x 19" Tall. 5 1/2" ID. 113lbs. 600/1200:5 amp Ratio. NSV-4.8kv BIL-60kv. JCD-3. New.
GE Transformer 2000/4000: 5amps Ratio
(TM) 755X031020
23" x 12" x 19" Tall.
Manufactured by GE
Alt. P/N:
GEcurrent transformer. 23" x 12" x 19" Tall. 5 5/8" ID. 2000/4000:5 amp Ratio. NSV-14.4kv BIL-110kv. 123 lbs. New.
Instrument Transformer 400: 5amps Ratio
(TM) 787-401
12" x 6 1/2" H
Alt. P/N:
Instrument Transformercurrent transformer. 12" x 6 1/2" H. 5 1/16" ID hole. 400:5 amp Ratio. NSV-600v BIL-10kv. 50-400Hz. New.
Cuttler Hammer 2000: 5amps Ratio
(TM) 135-202MR
9 1/8"W x 9 1/8" H x 3" Deep. 5 3/4" ID.
Alt. P/N:
Cutler Hammercurrent transformer. 9 1/8"W x 9 1/8" H x 3" Deep. 5 3/4" ID. 2000:5 amp Ratio. NSV-600v. 50-400Hz. Tapped Secondary. New in Box.
Kuhlman 1000/2000: 5amps Ratio
(TM) LG-25-585
24" x 13" x 21" Tall.
Manufactured by Kuhlman
Alt. P/N:
Kuhlmancurrent transformer. 24" x 13" x 21" Tall. 4 1/2" ID. 1000/2000:5 amp Ratio. NSV-25v BIL-150kv.
Pinetops 1000/2000: 5amps Ratio
(TM) LGX-25-585
23" x 10 " x 22 " Tall
Manufactured by Pinetops
Alt. P/N:
Pinetopscurrent transformer. 23" x 10 " x 22 " Tall. 4 1/2" ID. 1000:5 amp Ratio. NSV-25.5kv BIL-150kv. 116lbs. New. PNFO 31000X
Ritz 1000: 5amps Ratio
(TM) GIFD25-03ER
13" x 13" x 21" Tall.
Manufactured by Ritz
Alt. P/N:
Ritzcurrent transformer. 13" x 13" x 21" Tall. 5" ID. 1000:5 amp Ratio. NSV-25.5kv BIL-150kv.
Wideband/Pulse Current Transformer
(TM) 301X
17.5 pounds
High frequency 3dB cut-off - 2MHz (approximate)
Low frequency 3dB cut-off - 5Hz (approximate)
Pearson Electronics wideband/pulse current transformer. Model 301X. .01 volts/amp. 50,000 amps peak. 400 ac amps RMS. 200 ns risetime. UHF female connector. output: 50 Ω. 8" x 9"H x 2 5/8"W. 3 3/4" hole.