Low Profile PC Mount Toroidal Transformers
Primary: 110/230 volts 60 Hz
Secondary: 12/24 volts
(two 12V @ 133mA or one 12V @ 266mA or one 24v @ 133mA)
110/230v 60Hz Primary; Two secondaries 12v, 133ma, (No load 17.3v, 1.5ma), 70% eff. For 110v supply power, primaries must be parallel; for 230v operation, primaries must be in series. 44.7mmL x 44.7mmW x 19.5mmH, UL & VDE certifications, Maximum ambient temperature of 60°C
Primary: 110/230 volts 60 Hz
Secondary: 18/36 volts
(two 18V @ 89mA or one 18V @ 178mA or one 36V @ 89mA)
110/230v 60Hz Primary; Two secondaries 18v, 89ma, (No load 25.7v, 1.5ma), 70% eff. For 110v supply power, primaries must be parallel; for 230v operation, primaries must be in series. 44.7mmL x 44.7mmW x 19.5mmH, UL & VDE certifications, Maximum ambient temperature of 60°C
Primary: 110/230 volts 60 Hz
Secondary: 12/24 volts
(two 12V @ 208mA or one 12V @ 416mA or one 24V @ 208mA)
110/230v 60Hz Primary; Two secondaries 12v, 208ma, (No load 17v, 2ma), 68% eff. For 110v supply power, primaries must be parallel; for 230v operation, primaries must be in series. 49.7mmL x 49.7mmW x 19.5mmH, UL & VDE certifications, Maximum ambient temperature of 60°C
Primary: 110/230 volts 60 Hz
Secondary: 18/36 volts
(two 18V @ 139mA or one 18V @ 278mA or one 36V @ 139mA)
110/230v 60Hz Primary; Two secondaries 18v, 139ma, (No load 25.5v, 2ma), 68% eff. For 110v supply power, primaries must be parallel; for 230v operation, primaries must be in series. 49.7mmL x 49.7mmW x 19.5mmH, UL & VDE certifications, Maximum ambient temperature of 60°C
Primary: 110/230 volts 60 Hz
Secondary: 22/44 volts
(two 22V @ 114mA or one 22V @ 228mA or one 44v @ 114mA)
110/230v 60Hz Primary; Two secondaries 22v, 114ma, (No load 29.7v, 2ma), 68% eff. For 110v supply power, primaries must be parallel; for 230v operation, primaries must be in series. 49.7mmL x 49.7mmW x 19.5mmH, UL & VDE certifications, Maximum ambient temperature of 60°C
Primary: 110/230 volts 60 Hz
Secondary: 18/36 volts
(two 18V @ 417mA or one 18V @ 834mA or one 36V @ 417mA)
110/230v 60Hz Primary; Two secondaries 18v, 417ma, (No load 22.2v, 4ma), 80% eff. For 110v supply power, primaries must be parallel; for 230v operation, primaries must be in series. 60mmL x 60mmW x 26.3mmH, UL & VDE certifications, Maximum ambient temperature of 60°C
Primary: 110/230 volts 60 Hz
Secondary: 18/36 volts
(two 18V @ 972mA or one 18V @ 1.94A one 36V @ 972mA)
110/230v 60Hz Primary; Two secondaries 15v, 1.667 amp, (No load 17.3v, 8ma), 86% eff. For 110v supply power, primaries must be parallel; for 230v operation, primaries must be in series. 82.4mmL x 82.4mmW x 37.5mmH, UL & VDE certifications, Maximum ambient temperature of 40°C
Primary: 110/230 volts 60 Hz
Secondary: 18/36 volts
(two 9V @ 2.77A or one 9V @ 5.54A or one 18V @ 2.77A)
110/230v 60Hz Primary; Two secondaries 9v, 2.777amp, (No load 10.4v, 8ma), 86% eff. For 110v supply power, primaries must be parallel; for 230v operation, primaries must be in series. 82.4mmL x 82.4mmW x 37.5mmH, UL & VDE certifications, Maximum ambient temperature of 40°C
Primary: 110/230 volts 60 Hz
Secondary: 15/30 volts
(two 15V @ 1.66A or one 15V @ 3.32A or one 30V @ 1.66A)
110/230v 60Hz Primary; Two secondaries 15v, 1.667 amp, (No load 17.3v, 8ma), 86% eff. For 110v supply power, primaries must be parallel; for 230v operation, primaries must be in series. 82.4mmL x 82.4mmW x 37.5mmH, UL & VDE certifications, Maximum ambient temperature of 40°C
30VA PC Mount Step Up / Down Transformer 115/230v
(TP) IF-30-230
Primary: 115/230 volts
Secondary: 115/230 volts
Apparent Power: 30 VA
Signal PC mount step up / down transformer.